Power Fault Detected
Power Fault Detected
Error Class : 0x000a | Error Code: 0x0224
Symptom
A POST message displays: Power Fault Detected - FlexLOM
Cause
The FlexibleLOM is not fully seated on the connector.
Action
- Power down the server.
- Do one of the following:
- For non-blade or non-SL-series servers, unplug the server.
- For blade or SL-series servers, remove the server.
- Locate and reseat the indicated FlexibleLOM.
Support and Other Resources
For additional product information located in our user manuals, go to the Hewlett Packard Enterprise Library at http://www.hpe.com/info/enterprise/docs:
- User Guide
- Maintenance and Service Guide
To view Hewlett Packard Enterprise self-repair videos, go to:
- Customer Self Repair ( http://www.hpe.com/support/selfrepair)
- Customer Self Repair Services Media Library ( https://thesml.itcs.hpecorp.net/default.aspx)
For live assistance, go to the Contact Hewlett Packard Enterprise Worldwide website at http://www.hpe.com/assistance.
Hewlett Packard Enterprise believes in being unconditionally inclusive. Efforts to replace noninclusive terms in our active products are ongoing.