External Chassis Overheating
External Chassis Overheating
Error Class : 0x0002 | Error Code: 0x0014
Symptom
External Chassis Overheating (Chassis %1, Temperature Sensor %2, Location %3, Temperature %4).
Cause
- The processor heat sink is not installed as indicated in the server documentation.
- A supported fan is not installed in the server.
- An air baffle or blank is missing or not installed properly and causing a disruption of the airflow.
- Verify that all air baffles and required blanks, such as drive blanks, processor heat sink blanks, power supply blanks, and so on, are installed.
- Verify that the correct processor heat sink is installed.
- Verify that the correct fan is installed, if the system supports both standard fans and performance fans.
- User Guide
- Maintenance and Service Guide
- Troubleshooting
- Release Notes
- Customer Self Repair ( http://www.hpe.com/support/selfrepair)
- Customer Self Repair Services Media Library ( https://thesml.itcs.hpecorp.net/default.aspx)
Action
Check Fans, processor heat sink, and air baffles installation.