<title>Bulletin: (Revision) HPE SSDs - Certain Drive Models Will Stall and Reboot After Exceeding the 56,000 Hours in Use for Its Power-On Hours (POH)</title>
<meta content="text/html; charset=utf-8" http-equiv="Content-Type">
</head>
<body style="font-family: Arial, sans-serif, Verdana, Helvetica; color: black; font-size: smaller;">
<div id="docDisplayForSearch">
<table style="table-layout: fixed; width: 95%; margin-left:10px; margin-right:10px;" class="IE8" border="0" cellspacing="0" cellpadding="0">
<tr>
<td style="width: 95% ;WHITE-SPACE: normal; word-wrap: break-word; word-break: normal; padding-right: 4px;">
<div style="margin-left: 0em; margin-top: 1ex; margin-bottom: 1ex;" class="title">
<h1 style="font-size: 115%;  margin-top: 2ex; margin-bottom: 1ex;">Bulletin: (Revision) HPE SSDs - Certain Drive Models Will Stall and Reboot After Exceeding the 56,000 Hours in Use for Its Power-On Hours (POH)</h1>
</div>
<span style="margin-right: 5px;font-size: 8pt!important" class="metadata-span">Document Subtype:  Customer Bulletin</span><span style="margin-right: 5px;font-size: 8pt!important" class="metadata-span">Severity:  <span id="severity_value">High</span></span><span style="margin-right: 5px;font-size: 8pt!important" class="metadata-span">Document ID:  a00142174en_us</span><span style="margin-right: 5px;font-size: 8pt!important" class="metadata-span">Last Updated:  2025-01-30</span><span style="margin-right: 5px;font-size: 8pt!important" class="metadata-span">Document Version:  6</span>
<div style="margin-left: 0em; margin-top: 2ex; margin-bottom: 2ex;" class="content.description">
<h2 style="font-size: 110%;  margin-top: 2ex; margin-bottom: 1ex;">DESCRIPTION</h2>
<p style="margin-top: 0; margin-bottom: 2ex;">An anomaly in the firmware for certain SSDs will cause the drive to reboot. The rebooting frequency is periodic and will occur every half hour to an hour. This issue will only occur after the drive has been in use more than 56,000 hours (i.e., 6.5 years). The information on how long it has been in use is shown in the Power On Hours (POH) field.</p>
<div style="margin-top: 0; margin-bottom: 2ex;" class="para">
<ul style="margin-top: 0;" class="list">
<li style="margin-top:1ex; margin-bottom:0ex; margin-left:0;">If the drive is used for OS storage, this issue may cause the kernel to crash and a BSOD may occur. In very rare cases, some of the key files for the Operating System (OS) may be corrupted when the drive hangs in its reboot process, which will make an OS image necessary to recover data.<br>
<br>
</li>
<li style="margin-top:1ex; margin-bottom:0ex; margin-left:0;">If the drive is part of a RAID volume, then the volume will attempt to perform a rebuild which will cause the performance to drop. In addition, if the drive's reboot starts before the rebuild is completed, it will cause a volume rebuild to fail and trigger the rebuild cycle again and again, never to recover the RAID volume. If multiple disks in the RAID fail at the same time, the data may not be recoverable except through a restore from backup media.</li>
</ul>
</div>
<p style="margin-top: 0; margin-bottom: 2ex;">The HPE Smart Storage Administrator (SSA) utility will display the POH field entry in years. (If more information about this POH field is needed, refer to 
<a xmlns:dctm="http://www.documentum.com" href="https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-a00092478en_us" title="" target="_blank">HPE Smart Storage Administrator (SSA) &ndash; Quick Guide to Determine SSD Power on Hours.</a>
)</p>
<p style="margin-top: 0; margin-bottom: 2ex;">
<b>Note</b>: Each administrator for drive may display this POH information differently. (If necessary, access HPE Support Center to find the appropriate information on how to find the POH information.)</p>
<p style="margin-top: 0; margin-bottom: 2ex;">An opensource tool, "Smartmontools" can achieve the same function as the SSA utility. (To use this opensource tool, locate and install the appropriate version of 
<a href="https://www.smartmontools.org/wiki/Download" title="Non-HPE site" target="_blank">smartmontools&nbsp;<picture>
<source srcset="/resource3/hpsc/doc/image/hpweb_1-2_exit.gif"></source>
<img alt="Non-HPE site" src="/resource3/hpsc/doc/image/hpweb_1-2_exit.gif" style="height:auto;max-width:100%;"></picture>
</a>
 and follow the distribution tips for the smartmontools installation.)</p>
<p style="margin-top: 0; margin-bottom: 2ex;">For example, in smartmontools to discover if the drive has been in use for more than 6.5 years or 3,418,669.8 minutes, use the following commands:</p>
<p style="margin-top: 0; margin-bottom: 2ex;">alf-rmc-sdf-p0:~ # smartctl --scan<br>/dev/sda -d scsi # /dev/sda, SCSI device<br>/dev/bus/0 -d megaraid,6 # /dev/bus/0 [megaraid_disk_06], SCSI device<br>/dev/bus/0 -d megaraid,7 # /dev/bus/0 [megaraid_disk_07], SCSI device<br>/dev/bus/0 -d megaraid,9 # /dev/bus/0 [megaraid_disk_09], SCSI device<br>/dev/bus/0 -d megaraid,10 # /dev/bus/0 [megaraid_disk_10], SCSI device<br>alf-rmc-sdf-p0:~ # <b>smartctl -d megaraid,6 -a /dev/sda</b>
<br>smartctl 7.2 2021-09-14 r5237 [x86_64-linux-5.14.21-150400.24.111-default] (SUSE RPM)<br>Copyright (C) 2002-20, Bruce Allen, Christian Franke, 
<a href="http://www.smartmontools.org" title="Non-HPE site" target="_blank">www.smartmontools.org&nbsp;<picture>
<source srcset="/resource3/hpsc/doc/image/hpweb_1-2_exit.gif"></source>
<img alt="Non-HPE site" src="/resource3/hpsc/doc/image/hpweb_1-2_exit.gif" style="height:auto;max-width:100%;"></picture>
</a>

</p>
<p style="margin-top: 0; margin-bottom: 2ex;">
<b>Note</b>: The Linux command in the example above may not be the same for your Operating System or Linux distribution.</p>
<p style="margin-top: 0; margin-bottom: 2ex;">
<i>Example</i>
</p>
<p style="margin-top: 0; margin-bottom: 2ex;">The data below is an example of a specific version of smartmontool output:</p>
<p style="margin-top: 0; margin-bottom: 2ex;">=== START OF READ SMART DATA SECTION ===<br>SMART Health Status: OK<br>
<br>Current Drive Temperature: 39 C<br>Drive Trip Temperature: 60 C<br>
<br>
<b>Accumulated power on time, hours:minutes 31326:50 </b>
</p>
<p style="margin-top: 0; margin-bottom: 2ex;">Manufactured in week 34 of year 2017<br>Specified cycle count over device lifetime: 10000<br>Accumulated start-stop cycles: 506<br>Specified load-unload count over device lifetime: 300000<br>Accumulated load-unload cycles: 1830<br>Elements in grown defect list: 0</p>
<p style="margin-top: 0; margin-bottom: 2ex;">SMART Attributes Data Structure revision number: 10<br>Vendor Specific SMART Attributes with Thresholds:<br>ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE<br>1 Raw_Read_Error_Rate 0x000f 077 064 044 Pre-fail Always - 50079291<br>3 Spin_Up_Time 0x0003 095 095 070 Pre-fail Always - 0<br>5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0<br>7 Seek_Error_Rate 0x000f 091 064 030 Pre-fail Always - 1358777742<br>
<b>9 Power_On_Hours 0x0032 050 050 000 Old_age Always - 43804</b>
<br>10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0<br>180 Unknown_HDD_Attribute 0x003b 100 100 030 Pre-fail Always - 48312991<br>194 Temperature_Celsius 0x0022 039 047 000 Old_age Always - 39 (0 18 0 0 0)<br>196 Reallocated_Event_Count 0x0033 100 100 010 Pre-fail Always - 0</p>
</div>
<div style="margin-left: 0em; margin-top: 2ex; margin-bottom: 2ex;" class="scope">
<h2 style="font-size: 110%;  margin-top: 2ex; margin-bottom: 1ex;">SCOPE</h2>
<p style="margin-top: 0; margin-bottom: 2ex;">Any HPE server that supports the following SSDs, when the Power On Hours (POH) information indicates it exceeds 56,000 hours or 6.5 years:</p>
<div style="margin-top: 0; margin-bottom: 2ex;" class="para">
<table style="font-size: '100%'; width: 100%;" cellspacing="0" cellpadding="4" border="0" class="ods_si_table_bordered">
<tbody>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>Drive Models</b></td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>Descriptions</b></td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>P/Ns</b></td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000400JWDKP</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 400GB SAS Write Intensive SFF Standard Carrier DS Solid State Drive</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873349-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000400JWDKP</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 400GB SAS 12G Write Intensive 3yr Wty EO000400JWDKP Solid State Drive (SSD)</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873351-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000800JWDKQ</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 800GB SAS Write Intensive SFF Standard Carrier DS Solid State Drive</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873460-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000800JWDKQ</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 800GB SAS 12G Write Intensive 3yr Wty EO000800JWDKQ SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873355-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO001600JWDKR</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 1.6TB SAS 12G Write Intensive 3yr Wty EO001600JWDKR SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873357-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO000400JWDKU</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 400GB SAS 12G Mixed Use 3yr Wty MO000400JWDKU SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873359-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO000800JWDKV</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 800GB SAS 12G Mixed Use 3yr Wty MO000400JWDKU SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873363-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO001600JWDLA</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 1.6TB SAS 12G Mixed Use 3yr Wty MO001600JWDLA SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873365-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO003200JWDLB</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 3.2TB SAS 12G Mixed Use 3yr Wty MO003200JWDLB SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">873367-B21</td>
</tr>
</tbody>
</table>
</div>
<p style="margin-top: 0; margin-bottom: 2ex;">
<br>
</p>
<p style="margin-top: 0; margin-bottom: 2ex;">
<br>
</p>
<div style="margin-top: 0; margin-bottom: 2ex;" class="para">
<table style="font-size: '100%'; width: 100%;" cellspacing="0" cellpadding="4" border="0" class="ods_si_table_bordered">
<tbody>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>Drive Models</b></td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>Descriptions</b></td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>P/Ns</b></td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000400JWUGC</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 400GB SAS WI SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09098-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000800JWUGD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 800GB SAS WI SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09100-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO001600JWUGE</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 1.6TB SAS WI SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09102-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO000400JWUFT</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 400GB SAS MU SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09088-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO000800JWUFU</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 800GB SAS MU SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09090-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO001600JWUFV</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 1.6TB SAS MU SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09092-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO003200JWUGA</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 3.2TB SAS MU SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09094-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO006400JWUGB</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 6.4TB SAS MU SFF SC DS SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P09096-B21</td>
</tr>
</tbody>
</table>
</div>
<p style="margin-top: 0; margin-bottom: 2ex;">
<br>
</p>
<p style="margin-top: 0; margin-bottom: 2ex;">
<br>
</p>
<div style="margin-top: 0; margin-bottom: 2ex;" class="para">
<table style="font-size: '100%'; width: 100%;" cellspacing="0" cellpadding="4" border="0" class="ods_si_table_bordered">
<tbody>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>Drive Models</b></td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>Descriptions</b></td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;"><b>P/Ns</b></td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000400JXBEU</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 400GB SAS WI SFF SC SSD<br> HPE 400GB SAS WI SFF BC SS540 SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P21125-B21<br> P40576-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO000800JXBFL</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 800GB SAS WI SFF SC SSD<br> HPE 800GB SAS WI SFF BC SS540 SSD<br>HPE 800GB SAS WI SFF BC SS540 SPL SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P21127-B21<br> P40577-B21<br>P49167-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">EO001600JXBFN</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 1.6TB SAS WI SFF SC SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P21129-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO000800JXBEV</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 800GB SAS MU SFF SC MV SSD<br> HPE 800GB SAS MU SFF SC SSD<br> HPE 800GB SAS MU SFF BC SS540 SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P49046-B21<br> P21131-B21<br> P40573-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO000960JXBFA</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 960GB SAS RI SFF SC MV SSD<br> HPE 960GB SAS RI SFF SC SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P49028-B21<br>P21139-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO001600JXBFP</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 1.6TB SAS MU SFF SC SSD<br>HPE 1.6TB SAS MU SFF SC MV SSD<br>HPE 1.6TB SAS MU SFF BC SS540 SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P21133-B21<br>P49048-B21<br>P40574-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO001920JXBFT</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 1.92TB SAS RI SFF SC MV SSD<br>HPE 1.92TB SAS RI SFF SC SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P49030-B21<br>P21141-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO003200JXBFQ</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 3.2TB SAS MU SFF SC MV SSD<br>HPE 3.2TB SAS MU SFF SC SSD<br>HPE 3.2TB SAS MU SFF BC SS540 SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P49052-B21<br>P21135-B21<br>P40575-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO003840JXBFU</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 3.84TB SAS RI SFF SC MV SSD<br>HPE 3.84TB SAS RI SFF SC SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P49034-B21<br>P21143-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO006400JXBFR</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 6.4TB SAS MU SFF SC MV SSD<br>HPE 6.4TB SAS MU SFF SC SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P49056-B21<br>P21137-B21</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO007680JXBGA</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 7.68TB SAS RI SFF SC SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P21145-B21</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">MO015360JXBFV</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">HPE 15.36TB SAS RI SFF SC MV SSD<br>HPE 15.36TB SAS RI SFF SC SSD</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">P49044-B21<br>P21147-B21</td>
</tr>
</tbody>
</table>
</div>
<p style="margin-top: 0; margin-bottom: 2ex;">
<br>
<b>Note</b>: HPE Gen10 systems do not support the MegaRaid (MR) Controllers or VROC, and instead support the HPE MCHP series of Smart Array Controllers. (VROC support starts with HPE Gen10 Plus systems.)</p>
<p style="margin-top: 0; margin-bottom: 2ex;"></p>
</div>
<div style="margin-left: 0em; margin-top: 2ex; margin-bottom: 2ex;" class="resolution">
<h2 style="font-size: 110%;  margin-top: 2ex; margin-bottom: 1ex;">RESOLUTION</h2>
<p style="margin-top: 0; margin-bottom: 2ex;">To correct and prevent this issue, update the Solid State Drives (SSDs) to the appropriate version for the operating systems.</p>
<p style="margin-top: 0; margin-bottom: 2ex;">Use the critical firmware <b>version HPD3</b> (Aug 7, 2024) for the following drive models:</p>
<p style="margin-top: 0; margin-bottom: 2ex;">

<a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-ae8b95207bc94848&amp;tab=revisionHistory&amp;softwareId=MTX_55e72303528c4a9b9754aa40fe" title="" target="_blank">Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ,            EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB            Drives</a>

</p>
<p style="margin-top: 0; margin-bottom: 2ex;">

<a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-896ea0712e9c4853&amp;tab=releaseNotes" title="" target="_blank">Online HDD/SSD Flash Component for Linux (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives</a>

</p>
<p style="margin-top: 0; margin-bottom: 2ex;">

<a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-d54c971d2c304756&amp;tab=releaseNotes" title="" target="_blank">Online HDD/SSD Flash Component for VMware ESXi - EO000400JWDKP, EO000800JWDKQ,            EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB            Drives</a>

<br>
<br>
</p>
<p style="margin-top: 0; margin-bottom: 2ex;">Use the critical firmware <b>version HPD4</b> (Nov 21, 2024) for the following drive models:</p>
<p style="margin-top: 0; margin-bottom: 2ex;">

<a href="https://support.hpe.com/connect/s/softwaredetails?collectionId=MTX-dab6093d4d7545e8" title="" target="_blank">Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives</a>

</p>
<p style="margin-top: 0; margin-bottom: 2ex;">

<a href="https://support.hpe.com/connect/s/softwaredetails?collectionId=MTX-07a5f3ddb9bd4168" title="" target="_blank">Online HDD/SSD Flash Component for Linux (x64) - MO000400JWUFT, MO000800JWUFU,            MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and            EO001600JWUGE Drives</a>

<br>
<br>

<a href="https://support.hpe.com/connect/s/softwaredetails?collectionId=MTX-d7a820130b1346d2" title="" target="_blank">Online HDD/SSD Flash Component for VMware ESXi - MO000400JWUFT, MO000800JWUFU,            MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and            EO001600JWUGE Drives</a>

<br>
<br>
</p>
<p style="margin-top: 0; margin-bottom: 2ex;">Use the critical firmware <b>version HPD2</b> (Jan 21, 2025) for the following drive models:</p>
<p style="margin-top: 0; margin-bottom: 2ex;">

<a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-f0e80dda550e4229&amp;tab=releaseNotes" title="" target="_blank">Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives</a>

</p>
<p style="margin-top: 0; margin-bottom: 2ex;">

<a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-8d0bd1ce26004a9e&amp;tab=releaseNotes" title="" target="_blank">Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives</a>

<br>
<br>

<a href="https://support.hpe.com/connect/s/softwaredetails?language=en_US&amp;collectionId=MTX-d0558c4ca40d4c18&amp;tab=releaseNotes" title="" target="_blank">Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives</a>

</p>
<p style="margin-top: 0; margin-bottom: 2ex;">
<br>
<br>
<br>
</p>
<p style="margin-top: 0; margin-bottom: 2ex;">
<br>
</p>
<div style="margin-top: 0; margin-bottom: 2ex;" class="para">
<table style="font-size: '100%'; width: 100%;" cellspacing="0" cellpadding="4" border="0" class="ods_si_table_bordered">
<tbody>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Document Version</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Release Date</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Details</div>
</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">6</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">January 30, 2025</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Updated the Resolution with firmware version HPD2 and Scope with part numbers and drive models: EO000400JXBEU; EO000800JXBFL; EO001600JXBFN; MO000800JXBEV; MO000960JXBFA; MO001600JXBFP; MO001920JXBFT; MO003200JXBFQ; MO003840JXBFU; MO006400JXBFR; MO007680JXBGA; MO015360JXBFV.</div>
</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">5</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">December 12, 2024</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Updated the Scope with correct drive models.</div>
</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">4</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">November 26, 2024</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Updated the Resolution with firmware version HPD4.</div>
</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">3</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">October 16, 2024</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Updated the Scope section with the two Standard Carrier drive models, EO000400JWDKP (873349-B21) and EO000800JWDKQ (873460-B21).</div>
</td>
</tr>
<tr class="ods_si_tr_even">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">2</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">September 09, 2024</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Updated the Description section with opensource tool, smartmontools example.</div>
</td>
</tr>
<tr class="ods_si_tr_odd">
<td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">1</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">August 15, 2024</div>
</td><td style="padding-top:5px;padding-bottom:5px;padding-right:10px;">
<div class="para">Original Document Release.</div>
</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr xmlns="http://www.w3.org/1999/xhtml"/>
<div style="margin-left: 0em; margin-top: 0; margin-bottom: 0;" class="product_group_names">
<div style=" margin-top: 0; margin-bottom: 0; font-size: 100%; " class="para">
<b>Hardware Platforms Affected:  </b>HPE ProLiant DL360 Gen10 server, HPE ProLiant BL460c Gen10 Server Blade, HPE ProLiant DL380 Gen10 server, HPE ProLiant DL160 Gen10 server, HPE ProLiant DL180 Gen10 server, HPE ProLiant DL580 Gen10 server, HPE ProLiant XL450 Gen10 Server, HPE ConvergedSystem 750 for Virtualization, HPE ProLiant DL20 Gen10 server, HPE Apollo 2000 Gen10 Plus System, HPE Apollo 6500 Gen10 Plus System, HPE ProLiant DL345 Gen10 Plus server, HPE ProLiant DL360 Gen10 Plus server, HPE ProLiant DL380 Gen10 Plus server, HPE Apollo 4200 Gen10 Plus System, HPE ProLiant DL325 Gen11, HPE ProLiant DL320 Gen11, HPE ProLiant DL360 Gen11, HPE Alletra Storage Server 4120, HPE Alletra Storage Server 4140, HPE Integrity BL860c i4 Server Blade, HPE ConvergedSystem 700 (CS700), HPE Apollo 4500 Chassis</div>
</div>
<div style="margin-left: 0em; margin-top: 0; margin-bottom: 0;" class="operating_system_groups">
<p style="margin-top: 0; margin-bottom: 5px;">
<b>Operating Systems Affected:  </b>Not Applicable</p>
</div>
<div style="margin-left: 0em; margin-top: 0; margin-bottom: 0;" class="software_group_names">
<div style=" margin-top: 0; margin-bottom: 0; font-size: 100%; " class="para">
<b>Software Affected:  </b>Not Applicable</div>
</div>
<div style="margin-left: 0em; margin-top: 0; margin-bottom: 0;" class="ia_identifier">
<div style=" margin-top: 0; margin-bottom: 0; font-size: 100%; " class="para">
<b>Support Communication Cross Reference ID:  </b>SIK9754</div>
</div>
<div style="margin-left: 0em; margin-top: 1ex; margin-bottom: 1ex;" class="copyright.notice">
<div style=" margin-top: 0; margin-bottom: 2ex; font-size: 100%; text-align: center;" class="para">&copy;Copyright 2026 Hewlett Packard Enterprise Development LP</div>
<div style=" margin-top: 0; margin-bottom: 0; font-size: 100%; text-align: left;" class="para">Hewlett Packard Enterprise Development shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither HPE nor its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restoration. The information in this document is subject to change without notice. Hewlett Packard Enterprise Development and the names of Hewlett Packard Enterprise Development products referenced herein are trademarks of Hewlett Packard Enterprise Development in the United States and other countries. Other product and company names mentioned herein may be trademarks of their respective owners.</div>
</div>
</td>
</tr>
</table>
</div>
</body>
</html>